Review



proteome profiler human xl cytokine array kit  (R&D Systems)


Bioz Verified Symbol R&D Systems is a verified supplier
Bioz Manufacturer Symbol R&D Systems manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    R&D Systems proteome profiler human xl cytokine array kit
    Proteome Profiler Human Xl Cytokine Array Kit, supplied by R&D Systems, used in various techniques. Bioz Stars score: 96/100, based on 513 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/proteome profiler human xl cytokine array kit/product/R&D Systems
    Average 96 stars, based on 513 article reviews
    proteome profiler human xl cytokine array kit - by Bioz Stars, 2026-03
    96/100 stars

    Images



    Similar Products

    96
    R&D Systems proteome profiler human xl cytokine array kit
    Proteome Profiler Human Xl Cytokine Array Kit, supplied by R&D Systems, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/proteome profiler human xl cytokine array kit/product/R&D Systems
    Average 96 stars, based on 1 article reviews
    proteome profiler human xl cytokine array kit - by Bioz Stars, 2026-03
    96/100 stars
      Buy from Supplier

    95
    MedChemExpress human cytokine il 4
    Human Cytokine Il 4, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/human cytokine il 4/product/MedChemExpress
    Average 95 stars, based on 1 article reviews
    human cytokine il 4 - by Bioz Stars, 2026-03
    95/100 stars
      Buy from Supplier

    99
    Miltenyi Biotec human miltenyi biotec 130 092 657 cellquant calibrator kit biocytex 7208 msd custom u plex cytokine assay mesoscale discovery
    Human Miltenyi Biotec 130 092 657 Cellquant Calibrator Kit Biocytex 7208 Msd Custom U Plex Cytokine Assay Mesoscale Discovery, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/human miltenyi biotec 130 092 657 cellquant calibrator kit biocytex 7208 msd custom u plex cytokine assay mesoscale discovery/product/Miltenyi Biotec
    Average 99 stars, based on 1 article reviews
    human miltenyi biotec 130 092 657 cellquant calibrator kit biocytex 7208 msd custom u plex cytokine assay mesoscale discovery - by Bioz Stars, 2026-03
    99/100 stars
      Buy from Supplier

    96
    Miltenyi Biotec cytokines
    Analysis of <t>cytokines,</t> interleukins and endothelial mesenchymal transition markers. qPCR analysis of inflammation markers 2d (A) and 7d (B), inflammatory regulators 2d (E) and 7d (F) and EndMT markers 2d (G) and 7d (H) were performed in irradiated HCAECs with and without fenofibrate (Feno). The release of different cytokines including <t>GM-CSF,</t> <t>MCP-1</t> and IL-6 which were quantified using flow cytometry after 2d (C) and 7d (D). The error bars represent the standard deviation (±SD) (Two-way ANOVA, Tukey's multiple comparisons test; ∗ p ≤ 0.05; ∗∗ p ≤ 0.01; ∗∗∗p ≤ 0.001; ∗∗∗∗ p ≤ 0.0001; n = 3).
    Cytokines, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/cytokines/product/Miltenyi Biotec
    Average 96 stars, based on 1 article reviews
    cytokines - by Bioz Stars, 2026-03
    96/100 stars
      Buy from Supplier

    99
    Miltenyi Biotec macsplex cytokine kits
    Analysis of <t>cytokines,</t> interleukins and endothelial mesenchymal transition markers. qPCR analysis of inflammation markers 2d (A) and 7d (B), inflammatory regulators 2d (E) and 7d (F) and EndMT markers 2d (G) and 7d (H) were performed in irradiated HCAECs with and without fenofibrate (Feno). The release of different cytokines including <t>GM-CSF,</t> <t>MCP-1</t> and IL-6 which were quantified using flow cytometry after 2d (C) and 7d (D). The error bars represent the standard deviation (±SD) (Two-way ANOVA, Tukey's multiple comparisons test; ∗ p ≤ 0.05; ∗∗ p ≤ 0.01; ∗∗∗p ≤ 0.001; ∗∗∗∗ p ≤ 0.0001; n = 3).
    Macsplex Cytokine Kits, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/macsplex cytokine kits/product/Miltenyi Biotec
    Average 99 stars, based on 1 article reviews
    macsplex cytokine kits - by Bioz Stars, 2026-03
    99/100 stars
      Buy from Supplier

    99
    Miltenyi Biotec macsplex cytokine 12 kit
    Analysis of <t>cytokines,</t> interleukins and endothelial mesenchymal transition markers. qPCR analysis of inflammation markers 2d (A) and 7d (B), inflammatory regulators 2d (E) and 7d (F) and EndMT markers 2d (G) and 7d (H) were performed in irradiated HCAECs with and without fenofibrate (Feno). The release of different cytokines including <t>GM-CSF,</t> <t>MCP-1</t> and IL-6 which were quantified using flow cytometry after 2d (C) and 7d (D). The error bars represent the standard deviation (±SD) (Two-way ANOVA, Tukey's multiple comparisons test; ∗ p ≤ 0.05; ∗∗ p ≤ 0.01; ∗∗∗p ≤ 0.001; ∗∗∗∗ p ≤ 0.0001; n = 3).
    Macsplex Cytokine 12 Kit, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/macsplex cytokine 12 kit/product/Miltenyi Biotec
    Average 99 stars, based on 1 article reviews
    macsplex cytokine 12 kit - by Bioz Stars, 2026-03
    99/100 stars
      Buy from Supplier

    96
    Bio-Rad bio plex pro human th17 cytokine assay
    Analysis of <t>cytokines,</t> interleukins and endothelial mesenchymal transition markers. qPCR analysis of inflammation markers 2d (A) and 7d (B), inflammatory regulators 2d (E) and 7d (F) and EndMT markers 2d (G) and 7d (H) were performed in irradiated HCAECs with and without fenofibrate (Feno). The release of different cytokines including <t>GM-CSF,</t> <t>MCP-1</t> and IL-6 which were quantified using flow cytometry after 2d (C) and 7d (D). The error bars represent the standard deviation (±SD) (Two-way ANOVA, Tukey's multiple comparisons test; ∗ p ≤ 0.05; ∗∗ p ≤ 0.01; ∗∗∗p ≤ 0.001; ∗∗∗∗ p ≤ 0.0001; n = 3).
    Bio Plex Pro Human Th17 Cytokine Assay, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/bio plex pro human th17 cytokine assay/product/Bio-Rad
    Average 96 stars, based on 1 article reviews
    bio plex pro human th17 cytokine assay - by Bioz Stars, 2026-03
    96/100 stars
      Buy from Supplier

    94
    Bio-Techne corporation human high sensitivity cytokine a premixed magnetic luminex® performance assay
    Analysis of <t>cytokines,</t> interleukins and endothelial mesenchymal transition markers. qPCR analysis of inflammation markers 2d (A) and 7d (B), inflammatory regulators 2d (E) and 7d (F) and EndMT markers 2d (G) and 7d (H) were performed in irradiated HCAECs with and without fenofibrate (Feno). The release of different cytokines including <t>GM-CSF,</t> <t>MCP-1</t> and IL-6 which were quantified using flow cytometry after 2d (C) and 7d (D). The error bars represent the standard deviation (±SD) (Two-way ANOVA, Tukey's multiple comparisons test; ∗ p ≤ 0.05; ∗∗ p ≤ 0.01; ∗∗∗p ≤ 0.001; ∗∗∗∗ p ≤ 0.0001; n = 3).
    Human High Sensitivity Cytokine A Premixed Magnetic Luminex® Performance Assay, supplied by Bio-Techne corporation, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/human high sensitivity cytokine a premixed magnetic luminex® performance assay/product/Bio-Techne corporation
    Average 94 stars, based on 1 article reviews
    human high sensitivity cytokine a premixed magnetic luminex® performance assay - by Bioz Stars, 2026-03
    94/100 stars
      Buy from Supplier

    99
    Miltenyi Biotec macsplex cytokine t nk cell kit
    Analysis of <t>cytokines,</t> interleukins and endothelial mesenchymal transition markers. qPCR analysis of inflammation markers 2d (A) and 7d (B), inflammatory regulators 2d (E) and 7d (F) and EndMT markers 2d (G) and 7d (H) were performed in irradiated HCAECs with and without fenofibrate (Feno). The release of different cytokines including <t>GM-CSF,</t> <t>MCP-1</t> and IL-6 which were quantified using flow cytometry after 2d (C) and 7d (D). The error bars represent the standard deviation (±SD) (Two-way ANOVA, Tukey's multiple comparisons test; ∗ p ≤ 0.05; ∗∗ p ≤ 0.01; ∗∗∗p ≤ 0.001; ∗∗∗∗ p ≤ 0.0001; n = 3).
    Macsplex Cytokine T Nk Cell Kit, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/macsplex cytokine t nk cell kit/product/Miltenyi Biotec
    Average 99 stars, based on 1 article reviews
    macsplex cytokine t nk cell kit - by Bioz Stars, 2026-03
    99/100 stars
      Buy from Supplier

    Image Search Results


    Analysis of cytokines, interleukins and endothelial mesenchymal transition markers. qPCR analysis of inflammation markers 2d (A) and 7d (B), inflammatory regulators 2d (E) and 7d (F) and EndMT markers 2d (G) and 7d (H) were performed in irradiated HCAECs with and without fenofibrate (Feno). The release of different cytokines including GM-CSF, MCP-1 and IL-6 which were quantified using flow cytometry after 2d (C) and 7d (D). The error bars represent the standard deviation (±SD) (Two-way ANOVA, Tukey's multiple comparisons test; ∗ p ≤ 0.05; ∗∗ p ≤ 0.01; ∗∗∗p ≤ 0.001; ∗∗∗∗ p ≤ 0.0001; n = 3).

    Journal: Redox Biology

    Article Title: Fenofibrate attenuates the adverse effects of radiation on endothelial cells through modulation of ROS-NO signalling and inflammation

    doi: 10.1016/j.redox.2025.103994

    Figure Lengend Snippet: Analysis of cytokines, interleukins and endothelial mesenchymal transition markers. qPCR analysis of inflammation markers 2d (A) and 7d (B), inflammatory regulators 2d (E) and 7d (F) and EndMT markers 2d (G) and 7d (H) were performed in irradiated HCAECs with and without fenofibrate (Feno). The release of different cytokines including GM-CSF, MCP-1 and IL-6 which were quantified using flow cytometry after 2d (C) and 7d (D). The error bars represent the standard deviation (±SD) (Two-way ANOVA, Tukey's multiple comparisons test; ∗ p ≤ 0.05; ∗∗ p ≤ 0.01; ∗∗∗p ≤ 0.001; ∗∗∗∗ p ≤ 0.0001; n = 3).

    Article Snippet: Extracellular release of inflammatory cytokines (e.g., M-CSF, Granzyme B, IFN-γ, IL-2, IL-4, IL-6, IL-10, IL-17A, IL-21, MCP-1 (CCL2), Perforin and TNF-α) in cell culture supernatants were quantitatively measured based on a fluorescent bead-based system using MACSPlex Cytokine Kits (#130-125-800; Miltenyi Biotec, Germany) according to the manufacturer's protocol.

    Techniques: Irradiation, Flow Cytometry, Standard Deviation

    Proposed mechanism of action of fenofibrate in irradiated HCAECs in-vitro . Irradiation reduced NO signalling via inactivation of the PI3K–AKT–eNOS pathway, whereas fenofibrate reactivated this pathway and restored NO production (A). Consistent with this, irradiation increased ROS generation, NOX activity, MDA levels, and 3-NT levels, while fenofibrate mitigated this effect (B). Irradiation also triggered an inflammatory response, which was counteracted by fenofibrate (C). The released cytokines contribute to inflammation, changes in cytoskeleton organisation and initiation of EndMT, and fenofibrate effectively attenuated the processes (D). Alterations in the pathways described above play a crucial role in the remodelling of vascular endothelial cells involved in the initiation and progression of atherosclerosis. Fenofibrate acts to reduce or restore the effects of irradiation on these pathways (E–F). Solid lines indicate correlations validated in this study, while dashed lines indicate unvalidated correlations.

    Journal: Redox Biology

    Article Title: Fenofibrate attenuates the adverse effects of radiation on endothelial cells through modulation of ROS-NO signalling and inflammation

    doi: 10.1016/j.redox.2025.103994

    Figure Lengend Snippet: Proposed mechanism of action of fenofibrate in irradiated HCAECs in-vitro . Irradiation reduced NO signalling via inactivation of the PI3K–AKT–eNOS pathway, whereas fenofibrate reactivated this pathway and restored NO production (A). Consistent with this, irradiation increased ROS generation, NOX activity, MDA levels, and 3-NT levels, while fenofibrate mitigated this effect (B). Irradiation also triggered an inflammatory response, which was counteracted by fenofibrate (C). The released cytokines contribute to inflammation, changes in cytoskeleton organisation and initiation of EndMT, and fenofibrate effectively attenuated the processes (D). Alterations in the pathways described above play a crucial role in the remodelling of vascular endothelial cells involved in the initiation and progression of atherosclerosis. Fenofibrate acts to reduce or restore the effects of irradiation on these pathways (E–F). Solid lines indicate correlations validated in this study, while dashed lines indicate unvalidated correlations.

    Article Snippet: Extracellular release of inflammatory cytokines (e.g., M-CSF, Granzyme B, IFN-γ, IL-2, IL-4, IL-6, IL-10, IL-17A, IL-21, MCP-1 (CCL2), Perforin and TNF-α) in cell culture supernatants were quantitatively measured based on a fluorescent bead-based system using MACSPlex Cytokine Kits (#130-125-800; Miltenyi Biotec, Germany) according to the manufacturer's protocol.

    Techniques: Irradiation, In Vitro, Activity Assay